Home > Petroleum > Overfill Protection > Scully >

S20.09409 Scully 2-Wire Optic Probe

Scully Optic Sensor - 2 Wire Optic Probe, 7" Length, L1 SP-TO


 
Sale Price $179.88

Availability: Usually Ships in 24 to 48 Hours
Product Code: S20.09409
Quantity:

Description
 
Scully Optic Sensor - 2 Wire Optic Probe, 7" Length, L1 SP-TO

The new ScuL-Sense design eliminates temperature stresses and dramatically improves reliability across a wide temperature range. Scully two-wire optic sensors are designed for liquid petroleum product overfill prevention and point level detection. The new ScuL-Sense design eliminates temperature stresses and dramatically improves reliability across a wide temperature range. They are designed to be used with the Scully Intellitrol and ST-15 series gantry control monitors, and are also used with the Scully IntelliCheck Monitor. There is no waiting for the control monitors permit light to go on because the sensor requires no warm up time. They can be used for overfill prevention on road tankers, rail cars and storage tanks. The two-wire optic sensor incorporates Scully's unique and exclusive Dynacheck circuitry when connected to Scully monitoring equipment. To ensure that the system will always detect an overfill condition, the controller uses pulsed signals which continuously check the entire system operation, including sensors, wiring, connectors and itself. If a sensor comes in contact with liquid, or in the unlikely event of a system fault, the pulsed signals cease and the controller automatically signals for immediate shutdown of the loading operation. No operator involvement is needed. Shutdown is accomplished by controlling pumps or valves.
  • Maximum safety with Dynacheck Automatic and continuous self-checking circuitry when used with Scully loading rack controls and vehicle onboard monitors.
  • Solid state construction employing state-of-the-art components and technology
  • Scully's field-proven electro-optics technology.
  • Wide Temperature Range.
  • Employs easy to cut shaft when shorter length is needed.
  • Adjustable Sensing Level
  • Instant-On Instant permissive signal. No warmup time required.
  • Quick purging of liquid instant repermit as product level drops below the sensing point.
  • Fully compatible with all Scully optic controllers.
  • FM and CSA approvals for Class I, Division 1, Groups C and D hazardous locations
  • Meets requirements of API Recommended Practice RP-1004

Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

Petroleum > Overfill Protection > Scully
Petroleum > Overfill Protection
Petroleum